Get Flash Player

EtherCAT to AS-i

1 AS-i 3.0 master

 

Recognition of Duplicate AS-i addresses

 

AS-i Earth Fault Detector integrated

 

AS-i Noise Detector integrated

 

 

 

Art. no.

BW2162

Operating current

master power supply
approx. 200 mA out of AS-i circuit

Operating voltage

AS-i voltage 30 V DC

EtherCAT interface

according to IEEE 802.3 (RJ-45 connector)

Baud rates

10/100 MBaud

AS-i cycle time

150 μs*(number of slaves+ 2)

Displays

 

LCDs

displaying slave addresses and error messages

LED green (power)

Power on

LED green (ser active)

EtherCAT network active

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i normal operation active

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

the master is in configuration mode

Buttons

4

Voltage of insulation

≥ 500 V

EMC directions

EN 50 082, EN 50 081

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainlees steel

Dimensions (L, W, H)

120 mm, 85 mm, 83 mm

Protection category (DIN 40 050)

IP20

Tolerable loading refering to impacts and vibrations

according to EN 61 131-2

Weight

500 g

Accessories:

  • Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602)
  • Cross-Link cable (art. no. BW1304)

 

 

 

 

 

 

EtherCAT to AS-i

2 AS-i 3.0 Masters

 

Recognition of duplicate AS-i addresses

 

AS-i Earth Fault Detector integrated

 

AS-i Noise Detector integrated

 

BW2163: redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks

 

BW2164 in version 1 gateway, 1 power supply for 2 AS-i circuits:
only 1 gateway + 1 AS-i power supply for 2 AS-i networks

 

 

 

Art. no.

BW2163

BW2164

Operating current

master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA

version "1 power supply,
1 gateway for 2 AS-i circuits",
approx. 250 mA (PELV supply)

EtherCAT interface

according to IEEE 802.3 (RJ-45 connector)

Baud rates

10/100 MBaud

AS-i cycle time

150 μs*(number of slaves+ 2)

Displays

 

LCDs

displaying slave addresses and error messages

LED green (power)

power on

LED green (ser active)

EtherCAT network active

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i normal operation active

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

the master is in configuration mode

Buttons

4

Voltage of insulation

≥ 500 V

EMC directions

EN 50 082, EN 50 081

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainlees steel

Dimensions (L, W, H)

120 mm, 85 mm, 83 mm

Protection category (DIN 40 050)

IP20

Weight

500 g

Accessories:

  • Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602)
  • Cross-Link cable (art. no. BW1304)
  • Power supply 4A (art. no. BW1649)/8A (art. no. BW1593) for art. no. BWU1652