You need to upgrade your Flash Player or to allow javascript to enable Website menu.
Get Flash Player

CANopen-Gateway to AS-i
 

1 AS-i 3.0 master

 

Recognition of Duplicate AS-i addresses

 

Advanced Diagnostic Function

 

 

 

Art. no.

BWU1821

BWU2225

Operating current

power supply A, approx. 200 mA out of AS-i

Operating voltage

AS-i voltage 30 V DC

Terminals

CANopen (5-pin plug), RS 232 diagnostic interface

AS-i Master profile

Master profile M4 (AS-i Specification 3.0)

Baud rate

10/1000 KBaud

AS-i cycle time

150 μs* (Number of slaves + 2)

CANopen-Features

extended boot-up, minimum boot-up, life guarding
COB ID Distribution: DBT, SDO, Default
Node ID Distribution : SDO, Switch
No of PDOs : up to 35 Rx, 35 Tx
PDO Modes: async, cyclic, acyclic
Device Specification: CiA DS-301

Displays

 

LCD

displaying AS-i slave addresses and error messages

LED green (power)

voltage ON

LED green/red (MNS)

module/network status (MNS)

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i in normal operation

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

configuration mode active

Push-buttons

4 (mode/set)

Voltage of insulation

≥ 500 V

EMC directions

EN 50 295, EN 61 000-6-2, EN 61 000-6-4

Operating temperature

0 °C ... +55 °C

-25 °C ... +55 °C

Storage temperature

-25 °C ... +85 °C

Housing

housing in stainless steel

Dimensions (L, W, H)

120 mm, 85 mm, 83 mm

Protection category DIN 40 050)

terminals IP20

Tolerable loading refering to impacts and vibrations

according to EN 61 131-2

Weight

520 g

 

Accessories:

  • Software "AS-i-Control-Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602)
  • CANopen master simulator (art. no. BW1453)
  • Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
  • AS-i power supply 4 A (art. no. BW1649)

 

 
 
 
CANopen-Gateway to AS-i

 

2 AS-i 3.0 Masters

 

Recognition of Duplicate AS-i addresses

 

Advanced Diagnostic Function

 

BW1822: redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks

 

BWU1823 version 1 power supply, 1 gateway for 2 AS-i circuits:
only 1 gateway + 1 AS-i power supply for 2 AS-i networks!

 

 

 

 

Art. no.

BWU1822

BWU1823

Operating current

master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA

version "1 Power Supply, 1 Gateway for 2 AS-i
circuits", approx. 250 mA (PELV Supply)

Terminals

CANopen (5-pin plug)
RS 232 diagnostic interface

AS-i Master profile

Master profile M4 (AS-i Specification 3.0)

Baud rate

10/1000 KBaud

AS-i cycle time

150 μs* (Number of slaves + 2)

CANopen-Features

extended boot-up, minimum boot-up, life guarding
COB ID Distribution : DBT, SDO, Default
Node ID Distribution : SDO, Switch
No of PDOs: up to 70 Rx, 70 Tx
PDO Modes : async, cyclic, acyclic
Device Specification: CiA DS-301

Displays

 

LCD

displaying AS-i slave addresses and error messages

LED green (power)

voltage ON

LED green/red (ser active)

module/network status (MNS)

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i in normal operation

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

configuration mode active

Push-buttons

4 (mode/set)

Voltage of insulation

≥ 500 V

EMC directions

EN 50 295, EN 61 000-6-2, EN 61 000-6-4

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

housing in stainless steel

Dimensions (L, W, H)

120 mm, 85 mm, 83 mm

Protection category DIN 40 050)

terminals IP20

Tolerable loading refering to impacts and vibrations

according to EN 61131-2

Weight

520 g

590 g

 

Accessories:

  • Software "AS-i-Control-Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602)
  • CANopen master simulator (art. no. BW1453)
  • Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
  • AS-i power supply 4 A (art. no. BW1649)
  • Power supply 4 A (art. no. BW1597)/8 A (art. no. BW1598) for art. no. BWU1823

Информация взята с официального сайта компании Bihl+Wiedemann  http://www.bihl-wiedemann.de

 

О компании Продукция Производители Проекты Клиенты Контакты Карта сайта Форум