Каталог >> Техника автоматизации >> Bihl+Wiedemann >> BWU1818, BW1824, BWU1819, BW1825, BWU1820, BW1826

DeviceNet to AS-i bridge
 

1 AS-i 3.0 master

 

AS-i Earth Fault Detector integrated

 

Recognition of duplicate AS-i addresses

 

AS-i Noise Detector integrated

 

 

 

 

 

Art. no.

BWU1818

Art. no.

BW1824 Class 1 Div 2
(Group A, B, C & D, T-Code 4)

 

Operating current

power supply A, approx. 200 mA out of AS-i

Operating voltage

AS-i voltage 30 V DC

Terminals

DeviceNet interface (5-pin plug)
RS 232 diagnostic interface

AS-i Master profile

master profile M4 (AS-i specification 3.0)

AS-i cycle time

150 μs* (number of slaves + 2)

Displays

 

LCD

displaying AS-i slave addresses and error messages

LED green (power)

voltage ON

LED green/red (ser active)

module/network-status (MNS)

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i in normal operation

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

configuration mode active

Push-buttons

4 (mode/set)

Voltage of insulation

≥ 500 V

EMC directions

EN 50 295, EN 61 000-6-2, EN 61 000-6-4

Ambient operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainless steel

Dimensions (L, W, H)

120 mm, 85 mm, 83 mm

Protection category DIN 40 050)

terminals IP20

Tolerable loading referring to impacts and vibrations

according to EN 61 131-2

Weight

520 g

 

Accessories:

  • Software "AS-i Control Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602, s. See Article no. BW1602: Software AS-i Control Tools with serial cable for AS-i Master in Stainless Steel)
  • DeviceNet Master Simulator with USB interface (art. no. BW1420, s. See BW1420)
  • Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
  • AS-i Power Supply 4 A (art. no. BW1649, s. See Article no. BW1649 AS-i Power Supply 4 A, wide range power supply)

 

Pin assignment:

 

DeviceNet to AS-i Bridge

 

2 AS-i 3.0 Masters

 

AS-i Earth Fault Detector integrated

 

Recognition of duplicate AS-i addresses

 

AS-i Noise Detector integrated

 

BWU1819: redundant power supply out of AS-i:
all fundamental functions of the device remain available even in
case of power failure in one of the two AS-i networks

 

BWU1820, BW1826 in version
"1 Power Supply, 1 Gateway for 2 AS-i Circuits":
only 1 Gateway + 1 AS-i Power Supply for 2 AS-i Networks!

 

 

 

 

Art. no.

BWU1819

 

Art. no. BWU1820

Art. no.

 

BW1825 Class 1 DIv 2
(Group A, B, C & D, T-Code 4)

 

W1826 Class 1 Div 2
(Group A, B, C & D, T-Code 4)

 

Operating current

master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA

approx. 200 mA out of AS-i circuit 1
approx. 70 mA out of AS-i circuit 2

version "1 power supply,
1 gateway for 2 AS-i circuits",
approx. 250 mA (PELV supply)

Terminals

DeviceNet interface (5-pin plug) RS 232 diagnostic interface

AS-i master profile

master profile M4 (AS-i specification 3.0)

AS-i cycle time

150 μs* (number of slaves + 2)

Displays

 

LCD

displaying AS-i slave addresses and error messages

LED green (power)

voltage ON

LED green/red (ser active)

module/network status (MNS)

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i in normal operation

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

configuration mode active

Push-buttons

4 (mode/set)

Voltage of insulation

≥ 500 V

EMC directions

EN 50 295, EN 61 000-6-2, EN 61 000-6-4

Ambient operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainless steel

Dimensions (L, W, H)

120 mm, 85 mm, 83 mm

Protection category DIN 40 050)

terminals IP20

Tolerable loading referring to impacts and vibrations

according to EN 61 131-2

Weight

520 g

590 g

 

Accessories:

  • Software "AS-i Control Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602, s. See Article no. BW1602: Software AS-i Control Tools with serial cable for AS-i Master in Stainless Steel)
  • DeviceNet Master Simulator (art. no. BW1420, s. See BW1420)
  • Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
  • AS-i Power Supply 4 A (art. no. BW1649, s. See Article no. BW1649 AS-i Power Supply 4 A, wide range power supply)
  • Power Supply 4 A (art. no. BW1597)/8 A (art. no. BW1598) for art. no. BW1826 and BWU1820 (s. See BW1593)

Информация взята с официального сайта компании Bihl+Wiedemann  http://www.bihl-wiedemann.de

 